<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-06 01-47-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 42 dBuV EVROPA 2
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 6 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 68 kHz 18960 0,0158
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,4 dBr -0,11 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"EVROPA 2" 2204 10 (Pop M) 1 0 1 1 1:46, 6.05.2025
RT
"ALVARO SOLER - Animal "
AF EON
92.9, 94.6, 99.3, 99.5, 99.7, 101.5, 105.1, 105.5, 106.7 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 77 kHz: 0,0158 Acquired: 2025/05/06 1:47:03 Total samples: 18960 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,1 dBr MIN: -0,4 dBr AVE: -0,11 dBr % above 0,2 dBr: 0,0 Last value: -0,2 dBr (2025/05/06 1:47:02) 01:34 01:36 01:38 01:40 01:42 01:44 01:46 0 50 100 Dev. MAX [kHz] -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality